A straw bale construction of typical thickness (50 cm and more) does already meet the requirements for a passive house. Using typical conventional insulating materials (mineral wool, polystyrene, cellulose) the thickness needed is some 300 mm.
External walls are generally 10 to 12 inches wide. Homes that are built with rammed earth or heavy exterior masonry will have thicker walls. There is no limit to how thick an exterior wall can be.
In the walls: Typically, there is not an abundance of space inside your walls, so packing in the insulation isn’t a bad idea. To get an R-value of 13 to 16, you will need four to five inches of insulation. However, if you use a more effective type of insulation, you may be able to get away with less.
The level of insulation in Passive Houses U-values (thermal transmittance) of external walls, floor slabs and roof areas of Passive Houses range from 0.10 to 0.15 W/(m²K) (for Central European climate; these values may be slightly higher or lower depending on the climate).
External Wall Insulation on Passive Houses. So, as previously mentioned, Passive Houses require an outstanding amount of insulation; typically a Passive House wall will have a U-value of 0.15m/m2k.
Passive house design starts with continuous, super insulation around the building’s entire shell, insulating the slab, walls, and roof. To meet the performance metrics, Passive Homes generally require double the code minimum amount of insulation.
Most interior walls are constructed with 2-by-4 framing, and each 2-by-4 has a nominal width of 3 1/2 inches. Drywall typically covers both sides, and it’s usually 1/2 inch thick, which makes the wall 4 1/2 inches thick. Door jambs are typically milled to this width so the edges of the jabs come flush with the walls.
An interior wall should be at least 4 inches in thickness. If the wall features some plumbing like sinks, showers, or pipes, it should be thicker within the range of 6 to 8, even 12 inches depending on the type of building. Making walls too thick is wasteful, and if they are too thin, they are dangerous.
Solid walls are usually as thick as length of one standard brick (or 225mm). On buildings over 2 storeys, the lower walls might be “brick and a half” or 345mm thick.
Thickness Requirements for Load Bearing Masonry Wall The thickness of load bearing masonry wall should be at least 304.8 mm (1 ft.) thick for maximum wall height of 10.668m (35 ft.). Moreover, the thickness of masonry wall need to be increased by 101.6 mm (4in.)
The U value of a frame, called Uf value, indicates the heat transfer through the area of the frame and is based on DIN EN ISO 10077-2. The heat transfer is expressed in watts per square meter and Kelvin. The Uf value of a frame profile is determined automatically in WINISO®.
U-value (also known as U-factor) is a measure of heat transfer (heat gain or loss through glass), while R-value is a measure of heat resistance. U-value is not a material rating; it is a calculation of the conduction properties of various materials used in the construction of windows, doors and skylights.
Building Regulations U Values for Glass When renovating or extending a home the glazing elements must have a Uw value of 1.6 W/m2K or better. For a new build house you have to look at the energy requirements of the building as a whole but the glazing cannot have a Uw value of worse than 2.00 W/m2K.
Most passive house projects are new construction, but renovations can retrofit an existing apartment or house. These types of remodels require a full-scale commitment to saving energy. … “Add in triple-paned windows, a lot of insulation, and air sealing, and you’ll have an energy-efficient success.”
Insulated concrete form (ICF) construction provides the best solution to passive house design because they create air-tight walls with continuous insulation (CI), moisture resistance, and high thermal mass — vital components of a passive house design.
Typical recommendations for exterior walls are R-13 to R-23, while R-30, R-38 and R-49 are common for ceilings and attic spaces. See the Department of Energy’s (DOE) ranges for recommended levels of insulation below.
Passive House buildings are designed to be comfortable all year round – cozy and warm in winter (20°C), comfortably cool in summer (25°C).
Passive homes therefore do not rely on traditional heating sources like furnaces or boilers. Instead they use renewable energy sources like solar panels, geothermal energy or heat pumps.
Healthy and quiet The ventilation systems installed in Passive House buildings provide a constant supply of fresh air, ensuring pollutants and odours are removed from the building whilst maintaining a comfortable indoor air temperature.
You can increase the thickness of exterior walls when you do an interior remodel by using furring to extend depth, much as you would to make masonry walls ready to accept a drywall installation.
For brick walls, a common thickness is 230mm, and for concrete block walls, a common thickness is 200mm.
A typical residential wall consists of a floor plate, two ceiling plates, wall studs, and 1/2 inch drywall to form a wall that’s 4 1/2 inches thick. A narrow wall is 2 to 2 1/2 inches thick, but it is not suitable as a load bearing wall and local building codes might not allow it between bedrooms.
The minimum actual thickness of a load-bearing masonry wall shall be not less than 4 inches (102 mm) nominal or 33/8 inches (92 mm) actual thickness, and shall be bonded integrally with piers spaced in accordance with Section R606.
Therefore I recommend that all the walls should be at least 9 inch thick. 4.5-inch thick walls are not structurally safe if they are beyond 7 feet in height or carry some imposed load.
HEIGHT OF WALLSTHICKNESS8 ft. and under2 in.Over 8 ft. to 12 ft3 in.Over 12 ft. to 16 ft4 in.Over 16 ft. to 20 ft6 in.
It is expressed as watts per square metre, per degree Kelvin (W/m2K). The U-value is calculated from the reciprocal of the combined thermal resistances of the materials in the element, air spaces and surfaces.
A single pane of glass has an R-value of about 1. Homeowners often double this by adding a single-pane storm window. These insulation ratings compare to blown-in cellulose insulation with an R-value of 3.6 per inch of insulation.
Pilkington K Glass™ OW can be used as the inner pane (Surface 4) of an IGU to achieve a Ug-value as low as 0.9 when combined with Pilkington Optitherm™ S1 Pro T (Surface 2).
The lower the U-Factor, the better the window insulates. The SHGC measures how much of the sun’s heat comes through the window. It can range in value from 0 to 1. The lower the SHGC, the less solar heat the window lets in.
Energy-Efficient Glass Dual-pane glass insulates almost twice as well as single-pane, while triple-pane glass maximizes your energy efficiency. Inert argon gas can be used between panes of glass to improve insulating properties and help reduce thermal transfer.
The bottom line is this – triple pane windows are worth the additional cost if you plan on living in your house for anywhere from fifteen to twenty-five more years. … Triple-pane windows can be up to 20% more efficient than double-pane windows and up to 50 percent more efficient than single-pane windows.
Thermal bridging is the movement of heat across an object that is more conductive than the materials around it. The conductive material creates a path of least resistance for heat. Thermal bridging can be a major source of energy loss in homes and buildings, leading to higher utility bills.
Low-E coatings have been developed to minimize the amount of ultraviolet and infrared light that can pass through glass without compromising the amount of visible light that is transmitted. When heat or light energy is absorbed by glass, it is either shifted away by moving air or re-radiated by the glass surface.
Uw = thermal transmittance of window. Uf=thermal transmittance of the. frame. Af=visible area of the frame. Ug=thermal transmittance of the.